CLICK HERE to download a copy
Select Filter Diameter
Sample volume amount |
≤10 mL |
10-100mL |
Syringe filter diameter |
13mm |
30mm |
13mm Syringe Filters:
Housing: Virgin medical grade polypropylene (PP)
Filtration Area: 0.65cm²
Inlet: Female luer-lock
Outlet: Male luer-slip
Hold-up Volume: <25 µl
30mm Syringe Filters:
Housing: Virgin medical grade polypropylene (PP)
Filtration Area: 3.9cm²
Inlet: Female luer-lock
Outlet: Male luer-slip
Hold-up Volume: <100 µl
Select Pore Size of the Filter Membrane
Sample physical nature and analytical methods |
Filter membrane pore size |
Viscous materials or samples that contain high concentrations of solid particulate matter and mobile phase filtration |
0.45 µm |
HPLC samples to be analyzed with column packed with >3µm materials and GC, SFC, CE, GPC, and Flash samples |
0.45 µm |
HPLC samples to be analyzed with column packed with <3µm materials and GC, SFC, CE, GPC, and Flash samples |
0.22 µm |
General samples that contain fine particulate matter prior to GC, SFC, CE, GPC, and Flash samples, and sterile filtration |
0.22 µm |
Gas, liquid sample and solvent prior to GC, LC/MS and UHPLC, and other methods sensitive to particulate |
0.22 µm |
Select Filter Membrane According to the Sample Characteristics and Filtering Objective
Membrane Type |
Recommended Application |
Nylon |
Hydrophilic and commonly used for aqueous or mixed organic sample prep and HPLC, GC or dissolution sample analysis, such as bases, most HPLC solvents, alcohols, aromatic hydrocarbons, and THF. Not for strong acids, strong bases and high protein recovery. Excellent flow rates with most sample matrices and extremely low in extractables.
|
PTFE |
Hydrophobic and perfect for organic solvent-based, acidic or basic samples and all solvents, such as aggressive solvents, strong acids and bases, alcohols, and aromatics. Chemically resistant to all solvents and has an excellent thermal stability to high temperature fluids. It can be used with aqueous samples after pre-wetting with small amount of alcohol and then flushing with water.
|
PVDF |
Hydrophilic and excellent for HPLC and GC sample prep/clean up and protein-based samples due to broad chemical compatibility, the nature of a low protein binder, and low UV adsorbing extractables. It can be used for alcohols, weak acids, proteins, peptides and other biomolecules for high protein recovery. |
PES |
Hydrophilic and excellent for tissue culture, media, and buffers due to very low protein and nucleic acid binding and excellent flow rates. The PES membrane shows better chemical resistance than cellulose acetate. It is widely used in clinical/toxicology, ion chromatography, ICP-MS, AAS, and capillary electrophoresis for strong bases, alcohols, proteins, peptides.
|
MCE |
Hydrophilic and ideal for aqueous samples filtration that need higher flow rates and larger volume, including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, microbial analysis, cytology, HPLC samples prep/clean up, virus concentration, biological assays, food microbiology (enumeration of E. coli in foods), bacteriological studies. |
Select Filter Membrane According to aqueous/non-aqueous
Solvents |
Aqueous |
||||
Non-Aqueous |
Aqueous Mixtures |
Hydrophilic |
|||
Hydrophobic |
Hydrophilic |
Protein Analysis Biological Samples |
Sterilization Microbial Analysis |
HPLC and GC Biological Sample |
Solvent Mixtures Sample Prep |
PTFE |
Nylon |
PES |
MCE |
PVDF |
Nylon |